Maharashtra
08048055240
+918999813136

Dual Media Filter Manufacturer in Pune

Dual Media Filter • Turbidity & Suspended Solids Control

Dual Media Filter Manufacturer in Pune

Ethix provides Dual Media Filter (DMF) solutions for raw-water clarification, RO pre-treatment, commercial water systems and industrial applications. A DMF is selected to reduce turbidity, silt, suspended solids and visible particulate load before downstream treatment.

Request Technical Assessment Call Toll Free: 1800-123-6463
Quick answer: A Dual Media Filter is used primarily for sediment and turbidity control. It does not reduce TDS like an RO plant and it does not remove dissolved iron or hardness unless other appropriate stages are added.

Where This Solution Is Used

01

RO Pre-Treatment

Protect RO membranes from suspended solids and turbidity.

02

Borewell Water

Reduce silt, sand and particulate matter before downstream treatment.

03

Commercial Buildings

Support common raw-water filtration for utility-water systems.

04

Industrial Utility Water

Improve inlet-water quality for process, cooling or equipment-support lines.

05

STP / ETP Tertiary Stage

Use as a polishing filtration stage where the treatment route requires it.

06

Irrigation & Agriculture

Help reduce particulate load before suitable irrigation distribution systems.

Recommended Treatment / Project Flow

Every site should be designed after understanding water quality, flow, end use, available space and operating conditions. A typical project flow may include the following stages:

01

Inlet Water Review

Assess turbidity, suspended solids, flow and any iron/oil/organic concerns.

02

Media & Vessel Selection

Select vessel material, media layers, flow loading and valve arrangement.

03

Filtration Cycle

Raw water passes through graded media to retain suspended particles.

04

Backwash Planning

Provide a planned backwash sequence and drain route to restore filtration performance.

Information Needed for Correct System Sizing

Sharing the following details helps the Ethix technical team recommend a practical configuration instead of selecting equipment only by name or capacity.

Raw-Water Inputs

  • Turbidity / suspended solids
  • Iron, algae or oil concerns
  • Source and flow variation

Hydraulic Requirement

  • Required flow in LPM / m³/hr
  • Peak flow and operating hours
  • Available inlet pressure

Plant Integration

  • RO pre-treatment, WTP, STP/ETP or standalone use
  • Existing pumps and pipe size
  • Need for automation / multiport valve

Site Conditions

  • Footprint and height
  • Backwash water and drain line
  • Power and control-panel needs

Key Project Benefits

  • Reduces turbidity and suspended solids before downstream treatment.
  • Helps protect RO membranes, softener resin and selected equipment from particulate fouling.
  • Can be integrated into commercial, industrial and raw-water treatment trains.
  • Flow-based sizing supports a stable filtration rate and practical backwash schedule.
  • Available with suitable vessel, valve and control arrangement based on project duty.

How This Solution Differs From Other Water-Treatment Systems

System / StageMain RoleImportant Selection Point
Dual Media FilterReduces turbidity, silt and suspended solids.Needs backwash water and a drain connection.
Iron Removal FilterTargets iron/manganese-related water concerns.Selected by iron chemistry, pH and water analysis.
Activated Carbon FilterTargets chlorine, odour, colour and selected organics.Does not replace DMF for high suspended-solid load.
RO PlantReduces TDS and dissolved solids.Needs DMF/other pre-treatment to protect membranes.

Project Support Across Pune & Maharashtra

Ethix Water Solutions supports commercial and industrial enquiries from Pune, PCMC, Mumbai Metropolitan Region, Nashik, Kolhapur, Satara, Sangli, Chhatrapati Sambhajinagar, Nagpur and other Maharashtra locations. Site support is planned according to project scope; this page does not claim separate physical offices in every city.

Frequently Asked Questions

What does a Dual Media Filter remove?

A DMF is typically used for suspended solids, silt, sediment and turbidity. Its actual performance depends on media, filtration rate and raw-water characteristics.

Is a DMF required before RO?

In many RO projects, a DMF or other suitable pre-filtration stage is used to reduce particulate loading. The final pre-treatment is selected from the water report.

Does a DMF reduce TDS?

No. A DMF does not reduce dissolved TDS. An RO plant is selected when TDS reduction is required.

How often does a DMF need backwashing?

Backwash frequency depends on inlet-water turbidity, operating hours, pressure drop and system design.

Select a DMF Based on Flow, Turbidity & Backwash Requirement

Share your water report, process requirement, flow or daily demand, installation location, existing equipment and photos of the available space. Ethix can guide you toward the suitable treatment route and project configuration.

Send Enquiry Call +91 88885 20007